PM4500 series power meters

EasyLogic™ PM4500 series power meters provide the basic measurement capabilities required for monitoring single-phase or three-phase electrical installations (e.g., current, voltage and energy).

Meter Function Overview

EasyLogic™ PM4500 series power meters provide the basic measurement capabilities required for monitoring single-phase or three-phase electrical installations (e.g., current, voltage and energy).

The PM4500 series power meters support multiple functions, some of which are listed below:

  • LCD display screen: Equipped with an LCD segment display. Parameters can be viewed and operated via four front-panel buttons. Active, reactive and apparent energy readings Power factor measurement (True PF and Displacement PF)
  • LED pulse lamp for energy pulse indication
  • Terminal functions: Supports Modbus RTU, DL/T645 protocol communication Digital input Relay output: configurable for alarm and other functions

Meter Model

Model Product SKU Description
PM4513 METSEPM4513 Energy meter with LCD segment display, measures harmonics up to the 31st order, with 4DI and 2RO, supports Modbus RTU and DL/T645 communication protocols. Active energy meets accuracy class 0.5S, with carbon emission statistics.

Function Summary

Parameter PM4513
Measurement method Measurement input via CT (1A, 5A)
Wh accuracy class Class 0.5S(Class C)
varh accuracy class Class 2.0
Sampling rate per cycle 128
Current: ✓
• Per-phase and 3-phase average
• Calculated neutral current
Voltage: ✓
• Phase voltage – per-phase and 3-phase average
• Line voltage – per-phase and 3-phase average
Power factor ✓
• Per-phase and 3-phase total
Frequency ✓
Power: ✓
• Active power (kW)- Per-phase and total
• Reactive power (kvar)- Per-phase and total
• Apparent power (kVA)- Per-phase and total
3-phase unbalance CurrentVoltage
Demand parameters(kW, kVA, kvar, I) ✓
• Previous demand
• Current demand
• Predicted demand
• Peak demand: timestamped peak demand ⁽¹⁾
Energy: kWh, kVAh, kvarh 4 quadrantsExport (Input / Forward)Import (Output / Forward)Total (Export + Import) ⁽¹⁾Net (Export – Import) ⁽¹⁾
Meter runtime ⁽¹⁾ ✓
Load runtime ⁽¹⁾
THD %:
• Per-phase voltage L-N ✓
• Each line voltage L-L
• Per-phase current
Harmonics Up to 31st harmonic
Timestamped minimum / maximum values ⁽¹⁾ ✓
• Per-phase current
• Total active power
• Total apparent power
• Total reactive power
RTC ✓
Communication RS-485(Modbus RTU/DL/T645)
Digital input (4*DI) ✓
Relay output (2*RO) ✓
Energy pulse (pulse lamp) ✓

⁽¹⁾ Indicates features only readable via communication.