Outdoor Vacuum Circuit Breaker Type VBF

Outdoor Vacuum Circuit Breaker Type VBF

The Type VBF Outdoor Vacuum Circuit Breaker is an outdoor medium-voltage vacuum circuit breaker designed for high operational reliability and minimum maintenance. It is equipped with an ESH spring-operated mechanism and is suitable for outdoor installation in medium-voltage power distribution systems.

Product Overview

The Type VBF Outdoor Vacuum Circuit Breaker is an outdoor medium-voltage vacuum circuit breaker designed for high operational reliability and minimum maintenance. It is equipped with an ESH spring-operated mechanism and is suitable for outdoor installation in medium-voltage power distribution systems.

The breaker consists of three main assemblies: the pole assembly, the cabinet with operating mechanism, and the galvanized steel supporting structure. Each pole contains a vacuum interrupter, current transfer contacts, insulating pull rod, porcelain housing, and primary terminal connectors.

The operating mechanism is housed in a painted mild steel cabinet and includes a motor-charged spring mechanism, anti-condensation heater, status indicator, mechanical counter, auxiliary switches, control switches, anti-pumping relay, fuses, and terminal blocks.

The VBF breaker is designed for safe switching, fault interruption, remote or manual operation, and reliable outdoor service under harsh environmental conditions.

Product Features

Outdoor Medium-Voltage Design

Type VBF is designed specifically for outdoor medium-voltage applications. Its pole assemblies are housed in porcelain insulators and filled internally with insulating gas to support reliable outdoor operation.

Key features include:

· Outdoor live tank vacuum breaker structure

· Porcelain housing for pole insulation

· Vacuum interrupter technology

· Gas-filled pole assembly

· Galvanized steel supporting structure

· Painted mild steel operating cabinet

High Operational Reliability

The circuit breaker is equipped with a robust ESH operating mechanism using helical tension springs for both closing and opening operations.

Reliability features include:

· Simple and robust operating mechanism

· Spring-operated closing and tripping system

· Motor charging of closing spring

· Manual spring charging option

· Mechanical operation counter

· Status indication

· Anti-pumping relay

· Auxiliary switches for control and signaling

Low Maintenance Design

The VBF breaker is designed for long service life with minimized maintenance requirements.

Maintenance-related features include:

· Vacuum interrupter technology

· Spring-operated ESH mechanism

· Periodic maintenance intervals based on ambient condition

· Recommended spare parts list

· Clear troubleshooting and component replacement procedures

Safe Operation and Handling

The document provides detailed safety provisions for high-voltage equipment and stored-energy mechanisms.

Safety features and provisions include:

· Stored energy safety precautions

· Requirement to discharge closing and opening springs before work

· Earthing before maintenance

· High-voltage supply disconnection before service

· Warning categories for danger, warning, caution and important notes

· Porcelain insulator handling precautions

Flexible Installation Options

The breaker supports different installation arrangements, including standard installation and lower-height cabinet installation.

Installation options include:

· Cabinet attached to pole duct

· Cabinet installed at lower height using extended drive link and pipe assembly

· Foundation-mounted galvanized steel support structure

· High-voltage, low-voltage and earthing connections

Reliable Spring Charging System

The ESH mechanism allows both electrical and manual charging of the closing spring.

Charging features include:

· Motor-operated spring charging

· Manual charging handle

· Closing spring charged indication

· Motor cut-off switch

· Charging time less than 15 seconds

· Maximum manual charging force of 170 N

Main Functions

Medium-Voltage Circuit Switching

The VBF breaker provides switching and interruption for medium-voltage electrical circuits in outdoor applications.

Main switching functions include:

· Circuit closing

· Circuit opening

· Short-circuit interruption

· Load current switching

· Fault clearing

Vacuum Interruption

The breaker uses vacuum interrupters to interrupt current safely and efficiently.

Vacuum interruption supports:

· Fast arc extinction

· Reliable dielectric recovery

· Reduced maintenance compared with other interruption technologies

· Long operating life

Spring-Operated Closing and Opening

The ESH operating mechanism uses stored mechanical energy for breaker operation.

Functions include:

· Electrical spring charging

· Manual spring charging

· Electrical closing

· Mechanical closing

· Electrical tripping

· Mechanical tripping

· O-C-O operating capability without recharging

Remote and Local Operation

The operating cabinet includes control elements enabling both local and remote operation depending on control circuit arrangement.

Supported functions include:

· Local control through cabinet devices

· Remote open command

· Remote close command

· Auxiliary circuit connection through terminal blocks

· Status signaling through auxiliary contacts

Anti-Pumping Protection

The breaker includes an anti-pumping relay to prevent repeated closing operations when an open command is present or when the close command remains active.

This function improves safety and prevents mechanical stress.

Status Indication and Monitoring

The control cabinet provides operational feedback and status information.

Monitoring and indication functions include:

· Breaker open / closed status indication

· Spring charged / discharged indication

· Mechanical operation counter

· Auxiliary switch signaling

· Fuse and terminal block integration

Anti-Condensation Heating

The control cabinet is equipped with an anti-condensation heater to prevent moisture accumulation and support reliable operation, especially during storage or harsh outdoor conditions.

Commissioning and Testing

The instruction document defines commissioning checks before putting the breaker into service.

Commissioning tests include:

· Insulation resistance measurement

· Mechanical operation test

· Motor charging test

· Anti-pumping device test

· Heater function check

· Auxiliary circuit verification

Specifications

General Technical Data

Parameter

Specification

Product type Outdoor medium-voltage vacuum circuit breaker
Type designation VBF 36 16 25
Standard IEC 62271-100
Rated voltage 36 kV
Available voltage version Also available in 24 kV
Rated frequency 50 Hz
Insulation level 70 / 170 kVp
Rated normal current 1250 A / 1600 A
Short-circuit breaking current 26.3 kA
Operating sequence O – 0.3 s – CO – 3 min – CO
Weight Approximately 800 kg to 850 kg
Minimum ambient temperature -30°C

Pole Assembly

Component

Description

Number of poles Three separate poles
Mounting Mounted on a common duct
Interruption unit Vacuum interrupter / vacuum bottle
Current transfer Current transfer contacts
Mechanical linkage Insulating pull rod
Housing Porcelain insulator body
Primary terminals Terminal connectors such as NEMA 4
Internal filling SF6 or nitrogen gas
Filling pressure 1.5 bar absolute

Operating Mechanism and Cabinet

Item

Specification

Operating mechanism type ESH spring-operated mechanism
Cabinet material Painted mild steel
Spring system Helical tension springs for closing and opening
Spring charging Electrical motor or manual handle
Motor charging time Less than 15 seconds
Manual charging force Maximum 170 N
Operation capability O-C-O without recharging
Auxiliary switches 13 NO + 13 NC
Cabinet equipment Anti-condensation heater, status indicator, mechanical counter, control switches, anti-pumping relay, AC/DC fuses, terminal blocks

Steel Supporting Structure

Item

Specification

Structure material Galvanized steel
Function Supports breaker on foundation
Foundation bolts M20 bolts referenced for lower legs
Installation method Mounted on structure support angles

Installation Tools

Tool / Equipment

Specification

Erection crane 1500 kg capacity
Torque wrench 6 to 100 Nm
Standard spanners 7 mm to 43 mm
Lifting method Crane with slings or forklift

Electrical Connections

Connection Type

Specification

High-voltage connection M12 stainless steel or galvanized bolts
Terminal preparation Clean terminals with wire brush and apply conducting grease
Low-voltage connection Connect auxiliary circuits according to schematic diagram
Cable entry Removable gland plate
Earthing Connect securely to station earthing system
Earthing conductor requirement Cross-section not less than the earth connection pad

Commissioning Requirements

Test / Check

Requirement

MV circuit insulation resistance 2500 V Megger, minimum 200 MΩ
Auxiliary circuit insulation resistance 500 V Megger, several MΩ
Mechanical operation Manual charge and operation check
Motor charging Spring charging in less than 15 seconds
Anti-pumping test Breaker must not re-close under open command with close command still present
Heater check Space heater must be functional

Maintenance Intervals

Maintenance Operation

Normal Ambient

Dusty / Polluted Ambient

General inspection 2 years 1 year
Insulation measurement 4 years 2 years
Lubrication 2 years 1 year
Mechanism maintenance 5 years / 10,000 operations 3 years / 5,000 operations
Complete overhaul 10 years / 10,000 operations 5 years / 10,000 operations

ESH Mechanism Working Data

Function

Description

Spring charging method Electrical geared motor or manual handle
Closing operation Close release rotates half-shaft and releases closing lever
Tripping operation Open release actuates latch assembly and tripping spring opens the breaker
Motor cut-off Plastic cam activates motor cut-off switch after full charge
Closing spring indication Spring charged indication appears after manual or motor charging

Recommended Spare Parts

Spare Part

Part Number

Spring charging motor 15032
Tripping / closing coils 15030 A / B
Micro-switches 15033
Auxiliary switches 15027
Shock absorber 15007
Operating mechanism 15000A

 

Confirm The Right Outdoor Vacuum Circuit Breaker Type VBF Configuration

Send your voltage class, current rating, cabinet type, protection scheme, destination market and quantity. Kodery will review the request against the published product range.

Request a Quote