SACE Tmax Molded Case Circuit Breakers

SACE Tmax Molded Case Circuit Breakers

ABB SACE Tmax is a range of molded case circuit breakers and switch-disconnectors designed for special low-voltage applications requiring high breaking capacity, compact dimensions, flexible configurations, and advanced protection.

Product Overview

ABB SACE Tmax is a range of molded case circuit breakers and switch-disconnectors designed for special low-voltage applications requiring high breaking capacity, compact dimensions, flexible configurations, and advanced protection.

The range covers demanding electrical systems with operating voltages starting from 1000 V DC or 800 V AC, including photovoltaic systems, high-voltage AC distribution, DC networks, motor applications, and industrial power systems.

SACE Tmax products are available for both IEC and UL standard applications. The range includes dedicated solutions for:

· DC applications up to 1000 V DC

· Photovoltaic and high-voltage DC applications up to 1500 V DC

· AC applications up to 800 V AC

· AC applications up to 1150 V AC

· Switch-disconnector applications

· Motor protection applications

With advanced trip units, multiple execution versions, and a comprehensive accessory portfolio, SACE Tmax provides a reliable and flexible solution for special electrical installations.

Product Features

Special Application Coverage

SACE Tmax is designed for applications requiring higher voltage ratings than standard molded case circuit breakers.

The range supports:

· DC systems up to 1000 V DC

· PV and DC systems up to 1500 V DC

· AC systems up to 800 V AC

· AC systems up to 1150 V AC

· IEC and UL compliant installations

High Breaking Capacity in Compact Size

The Tmax range provides high short-circuit breaking capacities while maintaining compact molded case dimensions.

Key performance highlights include:

· Up to 50 kA at 1000 V DC

· Up to 25 kA at 1500 V DC

· Up to 50 kA at 800 V AC

· Up to 20 kA at 1000 V AC

· Up to 12 kA at 1150 V AC

Strong Construction and Safety

The range integrates construction features designed to improve operator safety and installation reliability.

Key safety features include:

· Double insulation

· Positive operation

· Isolation behavior

· Segregated accessory seats from power circuits

· Tropicalization for hot-humid climates

· Anti-corrosion treatments

· Glass-fiber reinforced synthetic resins

Flexible Installation Versions

SACE Tmax products are available in several installation executions.

Available versions include:

· Fixed version

· Plug-in version for T4 and T5

· Withdrawable version for T4, T5, T6 and T7

These solutions allow simplified maintenance, rapid replacement, and safe isolation.

Wide Range of Protection Trip Units

The range supports both thermomagnetic and electronic protection trip units.

Available trip units include:

· TMD

· TMA

· TMF

· PR221DS

· PR222DS/P

· PR222DS/PD

· Ekip M-LRIU

Protection can be configured for distribution, short-circuit protection, earth fault protection, motor protection, and communication-enabled applications.

DC and Photovoltaic Application Support

Dedicated versions are available for photovoltaic and high-voltage DC networks.

Key features include:

· Dedicated DC circuit breakers

· PV switch-disconnectors

· UL 489B solutions for North American PV applications

· Connection jumpers for DC pole series configurations

· Support for 2+2PS, 3PS and 4PS arrangements

Complete Accessory Portfolio

SACE Tmax supports a broad range of accessories for connection, control, signaling, operation, and safety.

Accessory categories include:

· Power terminals

· Service releases

· Motor operators

· Auxiliary contacts

· Communication modules

· Rotary handles

· Terminal covers

· Phase separators

· Plug-in and withdrawable kits

Main Functions

DC Circuit Protection

SACE Tmax molded case circuit breakers protect high-voltage DC networks against overloads and short-circuits.

Typical DC applications include:

· Photovoltaic plants

· Battery systems

· Industrial DC distribution

· Renewable energy installations

· High-voltage DC circuits

AC Circuit Protection

The range also supports high-voltage AC distribution networks up to 1150 V AC.

Typical AC applications include:

· Industrial distribution systems

· High-voltage low-voltage networks

· Special power supply systems

· Auxiliary distribution systems

Switch-Disconnection

SACE Tmax switch-disconnectors are used for disconnection, isolation, and switching functions in both AC and DC systems.

Available ranges include:

· T4D/PV to T7D/PV up to 1100 V DC

· T4D/PV-E to T7D/PV-E up to 1500 V DC

· AC switch-disconnector versions for special applications

Thermomagnetic Protection

Thermomagnetic trip units provide overload and short-circuit protection for AC and DC networks.

Available types include:

· TMD: fixed thermal and magnetic thresholds

· TMA: adjustable thermal and magnetic thresholds

· TMF: fixed thresholds for selected PV-E versions

TMA trip units provide:

· Adjustable thermal threshold: 0.7 to 1 x In

· Adjustable magnetic threshold: 5 to 10 x In

Electronic Protection

Electronic trip units provide enhanced protection and, in selected versions, communication capabilities.

Available electronic trip units include:

· PR221DS: L and S/I protection

· PR222DS/P: L, S, I and G protection

· PR222DS/PD: L, S, I and G protection with integrated Modbus RTU communication

Protection functions include:

· L overload protection

· S short-circuit protection

· I instantaneous short-circuit protection

· G earth fault protection

Motor Protection

The Ekip M-LRIU trip unit provides integrated protection for three-phase asynchronous motors.

Functions include:

· L overload protection

· R locked rotor protection

· I short-circuit protection

· U phase unbalance or phase loss protection

· G earth fault protection

· PTC sensor input

· Contactor control through PR212/CI module

· Modbus communication via system bus

Remote Opening and Closing

Service releases and motor operators enable remote control of the circuit breaker.

Available functions include:

· Shunt opening release

· Undervoltage release

· Shunt closing release for T7 motorizable versions

· Stored energy motor operators

· Spring charging motor for T7

Communication

Selected electronic trip units support communication functions.

Communication options include:

· Integrated Modbus RTU with PR222DS/PD

· Modbus via system bus with Ekip M-LRIU

· Ekip T&P configuration and test support

Key Specifications

Item

Specification

DC voltage range Up to 1000 V DC / 1500 V DC
AC voltage range Up to 800 V AC / 1150 V AC
Rated current range Up to 1600 A
DC breaking capacity Up to 50 kA at 1000 V DC; up to 25 kA at 1500 V DC
AC breaking capacity Up to 50 kA at 800 V AC; up to 20 kA at 1000 V AC; up to 12 kA at 1150 V AC
Standards IEC 60947-2, IEC 60947-3, UL 489B
Trip units TMD, TMA, TMF, PR221DS, PR222DS, Ekip M-LRIU
Installation versions Fixed, plug-in, withdrawable
Operating temperature -25°C to +70°C

 

Confirm The Right SACE Tmax Molded Case Circuit Breakers Configuration

Send your voltage class, current rating, cabinet type, protection scheme, destination market and quantity. Kodery will review the request against the published product range.

Request a Quote