GCS Low Voltage Withdrawable Switchgear

GCS Low Voltage Withdrawable Switchgear

GCS device is suitable for power distribution system in power plant, petroleum, chemical, metallurgy, textile, high-rise building and other industries. It’s three phase AC 50(60)Hz low-voltage complete set of distribution device with rated operating voltage of 380V (400V), (660V), and rated current of 4000A and below, and is used for power distribution of power generation and power supply, central control of motor and reactive power compensation in place requiring connecting with computer and of high degree of automation, like large power plants, petrochemical system.

Main application

GCS device is suitable for power distribution system in power plant, petroleum, chemical, metallurgy, textile, high-rise building and other industries. It’s three phase AC 50(60)Hz low-voltage complete set of distribution device with rated operating voltage of 380V (400V), (660V), and rated current of 4000A and below, and is used for power distribution of power generation and power supply, central control of motor and reactive power compensation in place requiring connecting with computer and of high degree of automation, like large power plants, petrochemical system.

Model and meaning

Model and meaning

Performance index

The design of the device meets the following standards:

● IEC439-1 Low-voltage switchgear and controlgear assemblies-Part 1: Type-tested and partially type-tested assemblies

● GB 7251 Low-voltage switchgear and controlgear assemblies Part 5 Assmeblies for power distribution in public networks

● ZBK 36001 low-voltage withdrawable switchgear

Basic technical parameter

Rated voltage of main circuit AC380(400)、(660)
Rated voltage of auxiliary circuit AC220、380(400); DC110、220
Rated frequency (Hz) 50(60)
Rated insulation voltage (V) 660(1000)
Rated current (A) Horizontal bus ≤ 4000
Vertical bus (MCC) 1000
Rated short time withstand current of bus (kA,1 s) 50,80
Rated peak withstand current of bus (kA/0.1s) 105,176
Power frequency test voltage (V/1 min) Main circuit 2500
Auxiliary circuit 1760
Bus 3 phase 4 wire system A.B.C.PE.N
3 phase 5 wire system A.B.C.PE.N
Protection level IP30,IP40

Device feature

● Improve the heat capacity of the adapter, and greatly reduce the additional temperature rise caused by the temperature rise of the adapter to the connectors, cable logs and spacers.

● The separation between functional units and compartments is clear and reliable, and the failure of one unit will not affect the work of other units so as to minimize the failure.

● The horizontal arrangement of the bus bar makes the device have good dynamic and thermal stability, and can withstand the impact of 80/71.76kA short-circuit current.

● The number of circuits in a single MCC switchgear is as many as 22, which fully considers the needs of large single-unit power generation, petrochemical systems and other industries for automated motor groups.

● The connection between the device and the external cable is completed in the cable compartment, and the cables can be entered and exited up and down. The current transformer is installed in the cable compartment to facilitate installation and maintenance.

● The same power distribution system can limit the short-circuit current through the matching of current-limiting reactors, stabilize the bus voltage at a certain value, and partially reduce the short-circuit strength requirements of the components.

● The drawer unit has a sufficient number of secondary connectors (32 pairs for 1 unit and above, 20 pairs for 1/2 unit), which can meet the requirements of the number of computer interfaces and automatic control circuits.

Auxiliary circuit

The design of the auxiliary circuit diagram conforms to the “Technical Regulations for the Design of Auxiliary Power for Thermal Power Plants” and other relevant design technical regulations. It is applicable to the low-voltage power system of power plants and substations and the low-voltage power distribution systems in factories and mining enterprises and high-rise buildings.

The auxiliary circuit solution is designed according to the main circuit solutions, which features the functional units of the power supply cable, the feeder (PC) and the motor feeder (MCC) for operation control.

Installation diagram

Installation diagram

Universal cabinet code A B C D Note
GCS-TG1010-4 1000 1000 850 956 Interconnection cabinet
GCS-TG0810-4 800 1000 650 956 Receiving cabinet
GCS-TG0808-4 800 800 650 756 Receiving cabinet
GCS-TG0608-4 600 800 450 756 Receiving cabinet

Fig. 2 PC cabinet installation diagram

Installation diagram

Universal cabinet code A B C D E FxG
GCS-TG1010-2 1000 1000 850 956 1000 400×400
GCS-TG0810-2 800 1000 650 956 800 200×400
GCS-TG1008-2 1000 800 850 756 1000 400×400
GCS-TG0808-2 800 800 650 756 800 200×400

Fig. 3 MCC cabinet installation diagram

Installation diagram

Universal cabinet code A B C D E FxG
GCS-TG1006-1 1000 600 850 556 60 400×350
GCS-TG0806-1 800 600 650 556 160 200×350

Ordering instruction

The order contract includes the following contents:

● The full model of the product includes the main circuit solution number and auxiliary circuit solution number

● Main circuit system combination sequence diagram

● Auxiliary circuit schematic diagram

● List of components in the cabinet

● Voltage, current, time and other setting parameters in the circuit

● Other special requirements inconsistent with the normal use of the product