BZM Molded Case Circuit Breaker

BZM Molded Case Circuit Breaker

The BZM series features a modular design, offering a range of protection options such as thermal-magnetic, magnetic-only, and earth-leakage protection.

Product Overview

The BZM series features a modular design, offering a range of protection options such as thermal-magnetic, magnetic-only, and earth-leakage protection.

Different protection units can be selected based on the specific protection requirements:

● Protection of power distribution cables supplied by transformers;

● Suitable for motor overload and short-circuit protection;

● Features low trip thresholds, making it suitable for protecting generators or long cable runs.

Technical parameters

Rated current of trip unit In(A) Rated current of trip unit In(A) Rated current of trip unit In(A) 10,16,20,25,32,40,50,63,80,100,125,140,160 100,125,140,160,180,200,225,250 250,315,350,400,500,630
Rated insulation voltage (V) Rated insulation voltage (V) Ui AC1000 AC1000 AC1000
Rated impulse withstand voltage (kV) Rated impulse withstand voltage (kV) Uimp 8 8 8
Rated operational voltage (V) Rated operational voltage (V) Ue AC400 AC400 AC400
Circuit breaker type Circuit breaker type Circuit breaker type N N N
Rated ultimate short-circuit breaking capacity (kV) Icu AC 50/60Hz,400V 400V 50 50 50
Rated service short-circuit breaking capacity (kV) Ics AC 50/60Hz,400V 400V 50 50 50
Rated ultimate short-circuit making capacity (kV) Icm AC 50/60Hz,400V 400V 105 105 105
Utilization category Utilization category Utilization category A A A
Operating cycle (maintenance-free) Mechanical   25000 25000 10000
Operating cycle (maintenance-free) Electrical AC400V 10000 10000 8000
Rated residual operating current IΔn(A) AC type residual current protection RSU type 0.03/0.05/0.1/0.3 0.03/0.05/0.1/0.3 —
Rated residual operating current IΔn(A) AC type residual current protection RNU type / RSX type / RNX type 0.05/0.1/0.3 0.05/0.1/0.3 —
Rated residual operating current IΔn(A) AC type residual current protection RSV type / RNV type / RSY type / RNY type 0.1/0.3/0.5/1.0 0.1/0.3/0.5/1.0 0.1/0.3/0.5/1.0
Rated residual non-operating current Rated residual non-operating current IΔno 1/2 IΔn 1/2 IΔn 1/2 IΔn
Rated residual short-circuit making (breaking) capacity Rated residual short-circuit making (breaking) capacity IΔm 1/4 Icu 1/4 Icu 1/4 Icu

BZM Molded Case Circuit Breaker

BZM Molded Case Circuit Breaker

BZM Molded Case Circuit Breaker

Confirm The Right BZM Molded Case Circuit Breaker Configuration

Send your voltage class, current rating, cabinet type, protection scheme, destination market and quantity. Kodery will review the request against the published product range.

Request a Quote