YB □ -12/0.4 Prefabricated Box Substation

YB □ -12/0.4 Prefabricated Box Substation

This product fully conforms to the standard of GB17467 “High Voltage and Low Voltage Prefabricated substation”. It is suitable for urban public power distribution, street lamp power distribution, industrial and mining enterprises, urban buildings, residential areas, oil fields, docks, hotels, parks and construction sites, etc. It can realize ring network or terminal power supply mode

Product overview

This product fully conforms to the standard of GB17467 "High Voltage and Low Voltage Prefabricated substation". It is suitable for urban public power distribution, street lamp power distribution, industrial and mining enterprises, urban buildings, residential areas, oil fields, docks, hotels, parks and construction sites, etc. It can realize ring network or terminal power supply mode

Model and meaning

Model and meaning

Service condition

● Altitude: ≤ 1000m;

● Ambient temperature: -25°C ~ +40°C;

● Temperature: Maximum monthly average temperature +30°C, maximum annual average temperature +20°C;

● Relative humidity: daily average not more than 95%, monthly average not more than 90%;

● Shock-proof level: horizontal acceleration 0.4m/s², vertical acceleration 0.15m/s²;

● The installation site has no severe impact, no serious pollution and chemical corrosion, no conductive dust and explosion risk, please negotiate with our company to solve when it does not meet the requirements of normal operating conditions.

Product structural feature

● This substation consists of a high-voltage room, a transformer room, and a low-voltage room, which can be arranged in a U-shape or a triangular shape;

● With terminal, ring network or dual power supply mode;

● It can be made into a single or double transformer power supply solution;

● Oil-immersed power transformer and dry-type power transformer can be selected;

● The box body is equipped with enough natural vents and heat insulation measures, which can ensure the normal operation of all electrical equipment (forced cooling can be used if users need)

● Complete "five prevention" function, convenient operation and maintenance, safe and reliable operation;

● The enclosure is made of stainless steel, aluminum alloy, cold-rolled plate, color steel composite plate, non-metal or a combination of two. It is anti-aging, flame retardant, anti-corrosion, waterproof, dustproof and adaptable to long-term outdoor use conditions;

● Small size, light weight, beautiful appearance and environment coordination;

● When SF6 load switch cabinet is used, the overall size of the box is small, which is more suitable for community construction and street lamp engineering renovation.

● High-voltage ring main unit can be equipped with network automation terminal (RTU) to realize reliable detection of short circuit and single-phase grounding fault. It has "four remote" function, which is convenient for automatic upgrade of distribution network.

Technical parameter

Item Unit Parameter
HV unit Rated frequency HZ 50
Rated voltage KV 6 10 35
Max. operating voltage KV 6.9 11.5 40.5
Rated current A 400、630
Transfer current A 870
Power frequency withstand voltage phase-eareth, phase-phase/isolating distance KV 42/48
Lightning impulse withstand voltage phase-eareth, phase-phase/isolating distance KV 75/85
Rated short circuit breaking current (current-limiting fuse) Rated short circuit breaking current KA 31.5
Transformer unit Rated voltage KV 6 10 35
Rated capacity KVA 10-1250
Tapping range % ±2×2.5%、±5%
Connection group Yyn0、Dyn11
Impedance voltage % 4、4.5、6、8
LV unit Rated voltage V 220、380、690、800
Rated current of main circuit A 50-4000
Branch current A 5-800
Enclosure Protection level (common product) HV room IP33; Transformer room IP23; LV room IP33
Noise level dB ≤ 50

lnstallation size diagram

lnstallation size diagram

Ordering instruction

Users need to provide the following information when ordering:

● Model, capacity, quantity, color and size requirements and enclosure materials;

● Model, performance, connection group, tapping range and impedance requirements of transformer;

● High and low voltage side primary wiring solution, components model, specifications and requirements;Transformer oil (#25, #45, high ignition point oil)

● Network configuration requirements of intelligent power management network or property management for box substation;

● Service environment requirements.

Construction drawings

Construction drawings

Confirm The Right YB □ -12/0.4 Prefabricated Box Substation Configuration

Send your voltage class, current rating, cabinet type, protection scheme, destination market and quantity. Kodery will review the request against the published product range.

Request a Quote